Skip to content
sayed.app

ResearchConference paper Accepted

Seismic Evaluation of a 58-Year-Old RC Academic Building

BSPP second-level screening of a legacy three-storey RC building at CUET.

Overview

A three-storey RC academic building at CUET has been in service for 58 years, predating modern seismic provisions such as BNBC. This study applies the BSPP Seismic Evaluation Manual (2nd Edition) second-level screening procedure to estimate its seismic demand and capacity.

The building has a total seismic weight of 16,945.5 kN and a fundamental period of 0.34 s. The equivalent design base shear is 3,982.2 kN, and the seismic demand index is 0.234. The calculated capacity satisfies the BSPP acceptance criterion (Is > Iso), indicating acceptable seismic performance.

The workflow combines structural weight estimation, demand evaluation, axial load analysis, ultimate member strength, ductility assessment, and seismic capacity calculation, and shows how second-level screening can guide retrofit decisions for legacy RC buildings.

Highlights

  1. 01

    Second-level screening

    BSPP 2nd Edition workflow from weight and demand to capacity.

  2. 02

    Demand vs capacity

    Demand index 0.234 with capacity above the BSPP acceptance threshold.

  3. 03

    Retrofit guidance

    Identifies where older RC buildings may need rehabilitation.